Task: Resolving Underclearance Spans Workshop
Task Description:
- Utilities oftentimes have a need to mitigate or raise underclearance transmission lines. These issues may arise due to line uprate projects, land development in transmission right-of-ways, or a variety of other sources.
- In partnership with EPRI Project 35.013, Overhead Line Ratings and Increased Power Flow, a workshop was planned to discuss utility experience and present a variety of solutions for resolving underclearance transmission spans.
Update:
- The Resolving Underclearance Spans Workshop was held on May 25th, 2023 with approximately 50 utility member attendees. Three North American utility engineers gave presentations discussing utility experience on this topic and EPRI presented 18 clearance resolution solutions.
- In 2024, EPRI plans to publish a technical report expanding upon the topics discussed at this workshop.
Video Updates
2024 Planned Deliverables
Product ID | Name |
Type |
---|---|---|
TBD | EPRI AC Transmission Line Reference Book and Applications: 200 kV and Above: 2024 Edition |
Technical Update |
TBD | Quantifying the Real Cost of Pole Material Options |
Technical Update |
TBD | Cost Effective Measures for the Resolution of Under-Clearance Spans |
Technical Update |
TBD | Safe Design Tension of ACSS Conductor: 2024 Edition |
Technical Update |
TBD | Optimal Line Tension Calculator Op10 v2.5 (Beta) |
Pre-Software |
TBD | Optimal Line Tension Calculator Op10 v2.5 |
Software |
TBD | Training Module on NESC 2024 Clearances |
Training Workshop |
2023 Completed Deliverables
Product ID | Name |
Type |
---|---|---|
3002026982 | EPRI AC Transmission Line Reference Book and Applications: 200 kV and Above: 2023 Edition |
Technical Update |
3002026983 | EPRI Transmission Line Reference Book: Conductor and Structure Motion, 2023 Edition |
Technical Update |
3002026986 | Optimal Pole Foundation Selection: 2023 Edition |
Technical Update |
3002026989 | New version of TLW-Gen2: Design Modules (Beta Software) |
Pre-Software |
3002026991 | New version of TLW-Gen2: Design Modules |
Software |
3002027324 | Safe Design tension of ACSS conductors |
Technical Update |
3002026992 | Applications of GIS-Based Line Design Tools |
Technical Update |
2022 Deliverables
Product ID | Name |
Type |
---|---|---|
3002024405 | EPRI AC Transmission Line Reference Book and Applications: 200 kV and Above: 2022 Edition |
Technical Update |
3002024408 | EPRI Transmission Line Reference Book: Conductor and Structure Motion, 2022 Edition |
Technical Update |
3002024409 | EPRI Transmission Line Reference Book: 115– 400 kV Compact Line Design, 2022 Edition |
Technical Update |
3002024410 | Optimal Pole Foundation Selection: 2022 Edition |
Technical Update |
3002024412 | Optimal Line Tension Calculator (Op10) ver 1.2 - Production Release |
Software |
3002024416 | New version of TLW-Gen2: Design Modules |
Software |
Key Deliverables
Product ID | Name |
Type |
---|---|---|
3002019001 | Guide for Coordination of Overhead Line Designs for Construction and Maintenance |
Technical Update |
3002015613 | Guide to Selection of Overhead Line Tension |
Technical Update |
3002012642 | AC Overhead Line Design Guide: 2018 Edition |
Technical Update |