This the multi-page printable view of this section. Click here to print.

Return to the regular view of this page.

Updates & Events

Info for members about events, updates, and results

Task: Guidelines for Thermo-Mechanical Design of Extruded Dielectric Cable Systems
Task Description: This multi-year task builds on and continues EPRI’s prior research in laboratory verification of thermo-mechanical behavior of extruded dielectric cables in ducts, pipes, and manholes. The report will include development of a validated source of practical engineering knowledge to assist cable engineers in designing extruded dielectric cable systems with respect to their thermo-mechanical effects. The report covers cable mechanical parameter measurements, finite element analysis modeling, engineering software tools, full-scale laboratory validation, applications at utility sites, and subject matter training.

Task: Advanced Sensors and Inspection Techniques for Extruded Dielectric Transmission Cable Systems
Task Description: This multi-year task is a continuation of the study on advanced sensors and monitoring techniques for inspection of cable system condition and operational status. The task covers developments of test rigs and performs tests to evaluate the effectiveness of available technologies and to demonstrate emerging technologies. Field trials on host utility cable circuits may be included to demonstrate technologies and collect measurement data from the fields.

Task: Aging Characteristics of Extruded Dielectric Cable Systems and Components
Task Description: Many extruded dielectric cable circuits are approaching 30-40 years in service. There is a need to develop an approach to study their management and life expectancy. This task is a series of laboratory experiments to better understand extruded dielectric cable system aging and failure mechanisms. This task is now expanded into three different tests:

  • Mechanical bending aging tests (30,000 to 60,000 cycles)
  • Full-scale thermo-mechanical aging tests (65, 80, 90 and 105 ºC)
  • Outdoor accelerated aging tests (138-kV and load currents)
    The aging tests are to include both land and submarine cables, and accessories of different designs at different transmission voltage levels

The aging tests are to include both land and submarine cables, and accessories of different designs at different transmission voltage levels.

Task: Asset Vintage Guide for Extruded Dielectric Cables, Terminations, and Joints
Task Description: How an asset degrades and fails is often dependent on how the asset was designed and manufactured. This task develops and updates vintage information for component materials, design, manufacturing, and other known issues of extruded dielectric cable systems.

Task: Quality Guidelines for Grouting Procedures for Large Casings Used for Transmission Cable Systems
Task Description: This report is an update of a prior EPRI research to document and evaluate utility experiences with grouting, describe steps required to properly design and install high-quality grouts, evaluate grout mixtures and installation procedures, describe quality control procedures, provide a summary of lessons learned, and provide a typical specification that utilities can use as a guide.

Task: Underground Transmission Vault Corrosion: Inspection Assessment and Remediation
Task Description: This task addresses common corrosion issues within underground extruded dielectric cable joint vaults. The report discusses corrosion mechanisms within the vaults and provides inspection and assessment results on components within the vaults. It also provides remediation recommendations based on results of field inspections and laboratory testing.

Task: Technology Review of Extruded Dielectric EHV Cable Systems, 220 to 500 kV
Task Description: This task is to build on prior EPRI studies on the same topic and provide a state-of-art technology review to assist utility cable users in making engineering decisions for reliable and cost-effective in-service operations. The report captures evolving technologies, success and failure experience, and lessons learned to enforce the needs for continuous vigilance during design, manufacturing and installation processes of both cables and accessories.

Engagement Opportunities

Meeting Scheduled Date Location Information
Underground Transmission Task Force - March 2025 March 10-13 (In Person) : March 17-20 (Virtual) Charlotte, NC Meeting Materials
Underground Transmission (Program 36) New Supplemental Launch Webcast March 31 1:00pm - 2:00pm ET Webcast Meeting Materials
EPRI R&D Project Update Webcast: Underground Transmission (P36) June 10 1:00pm - 2:30pm ET Webcast Meeting Materials
Underground Transmission 2025 ARP Rollout #1 June 17 1:00pm - 2:00pm ET Webcast Meeting Materials
EPRI R&D Project Update Webcast: High Voltage Direct Current Converter Stations and FACTS (P35.019, P36.008, P37.116) June 27 11:00am - 12:00pm ET Webcast Meeting Materials
Underground Transmission 2025 ARP Rollout #2 August 5 1:00pm - 2:30pm ET Webcast Meeting Materials
Underground Transmission Task Force August 18-22 (In Person) Charlotte, NC Meeting Materials
EPRI End of Year Webcast: High Voltage Direct Current Converter Stations and FACTS (P35.019, P36.008, P37.116) November 21 8:00am - 9:00am PT Webcast

2025 Planned Deliverables

Product ID Name Type
TBD

Guidelines for Thermo-Mechanical Design ofExtruded Dielectric Cable Systems in Pipes and Ducts Volume 1: Introductioninto EPRI Research Results - 2025 Update

Report
TBD

Guidelines for Thermo-Mechanical Design ofExtruded Dielectric Cable Systems in Pipes and Ducts Volume 2: Fundamentals -2025 Update

Report
TBD

Guidelines for Thermo-Mechanical Design ofExtruded Dielectric Cable Systems in Pipes and Ducts Volume 3: MechanicalParameter Tests - 2025 Update

Report
TBD

Guidelines for Thermo-Mechanical Design ofExtruded Dielectric Cable Systems in Pipes and Ducts Volume 4: Finite ElementAnalyses - 2025 Update

Report
TBD

Guidelines for Thermo-Mechanical Design ofExtruded Dielectric Cable Systems in Pipes and Ducts Volume 5: Full-scaleExperimental Verification Tests - 2025 Update

Report
TBD

Guidelines for Thermo-Mechanical Design ofExtruded Dielectric Cable Systems in Pipes and Ducts Volume 6: NormalizedSpan Methods and Software - 2025 Update

Report
TBD

Life Evaluation and Management of Extruded DielectricCable Systems and Components Volume 1: Composite Cable Termination Long-TermAging Tests - 2025 Update

Report
TBD

Life Evaluation and Management of ExtrudedDielectric Cable Systems and Components Volume 2: Cable Mechanical BendingAging Tests - 2025 Update

Report
TBD

Life Evaluation and Management of ExtrudedDielectric Cable Systems and Components Volume 3: Cable Thermo-MechanicalAging Tests - 2025 Update

Report
TBD

Life Evaluation and Management of ExtrudedDielectric Cable Systems and Components Volume 4: Asset Vintage Guide andTechnology Review - 2025 Update

Report
TBD

EPRI Guide on Extruded Transmission CableSystem Condition Monitoring and Diagnostics – 2025 Update

Report

2024 Deliverables

Product ID Name Tyep
3002029497

Guidelines for Thermo-Mechanical Design of Extruded Dielectric Cable Systems in Pipes and Ducts – Volume 1: Introduction into EPRI Research

Report

3002029498

Guidelines for Thermo-Mechanical Design of Extruded Dielectric Cable Systems in Pipes and Ducts-Volume 2: Fundamentals

Report

3002029499

Guidelines for Thermo-Mechanical Design of Extruded Dielectric Cable Systems in Pipes and Ducts-Volume 3: Mechanical Parameter Testing

Report

3002029500

Guidelines for Thermo-Mechanical Design of Extruded Dielectric Cable Systems in Pipes and Ducts: Volume 4 – Finite Element Analyses

Report

3002029501

Guidelines for Thermo-Mechanical Design of Extruded Dielectric Cable Systems in Pipes and Ducts - Volume 5: Full-Scale Experimental Verification Tests

Report

3002029502

Guidelines for Thermo-Mechanical Design of Extruded Dielectric Cable Systems in Pipes and Ducts–Volume 6: Normalized Span Methods and Software Design Guide

Report

3002029503

Underground Transmission Vault Corrosion: Inspection, Assessment, and Remediation: 2024 Update

Report

3002029504

Aging Characteristics of Extruded Dielectric Cable Systems and Components - Mechanical Bending Tests: 2024 Update

Report

3002029505

EPRI Guide on Extruded Transmission Cable System Condition Monitoring and Diagnostics-2024 Update

Report

3002029506

Asset Vintage Guide and Technology Review for Extruded Dielectric Cables, Terminations, and Joints: 2024 Update

Report