Task: EPRI Power Transformer Guidebook (Copper Book) 2025 update
Task Description: Each year EPRI publishes updates to the Copper Book to keep up-to-date with the latest research, technology developments and transformer standards. The guidebook has been written with the utility engineer and field staff as the audience and covers the entire range of topics from specification to end-of-life assessment. A valuable addition to the Copper Book is a growing list of quick-reference single page summaries of key topics. They have been designed to be conveniently printed for a pinboard or used electronically for quick guidance.
Update:
- 2025 updates include significant new material on alternative fluids and optimal DGA sampling techniques
Task: Technical webinars on the Transformer Guidebook.
Task Description: Multiple technical webinars based on chapters in the Transformer Guidebook are hosted each year. The webinar material is published for continued and convenient future access. Topics are selected to accelerate learning on key topics in the Transformer Guidebook (Copper Book).
Update:
- Two webinars are already complete (On-line DGA monitoring and Transformer Fundamentals).
- Three more are coming up: Novel fluids and materials, Optimal oil sampling practices and non-invasive transformer condition monitoring.
Task: Transformer online monitoring technologies: Laboratory testing to help members in specification development.
Task Description: A full 138-kV EPRI research substation has been commissioned and energized to support this research. EPRI laboratory test results are executed against a well-defined test protocol for online DGA monitors, online bushing monitors, on-line Partial Discharge monitors and on-line temperature monitors. The results provide valuable assistance in monitor specification, interpretation and adoption.
Update:
- Two new on-line DGA monitors are being added to the research laboratory and a new test setup for on-line bushing monitors is being commissioned in the EPRI Charlotte laboratories.
Task: Alternative transformers fluids for increased ratings, extended service life, and reduced environmental impact.
Task Description: Although hypotheses have been proposed, it is unknown why ester fluids extend the life of cellulose compared to naphthenic mineral oil. This research provides further insight into the dynamics of the interactions between thermally upgraded kraft (TUK) paper with insulating fluids and water. Enhanced imaging and sorption forces of different insulation fluids with TUK winding paper, as well as the kinetics of water formation from paper, will be studied to provide understanding into some of the insulating fluid-solid dynamics in transformers. The results will aid in determining what oil quality limits should be set for in-service equipment with some esters, as well as what conditions a transformer owner should use or avoid, so as to not lose the life extension properties of esters compared to naphthenic mineral oil.
Additionally, studies concerning the precision and accuracy of using on-line DGA monitors to assess the properties of different alternative fluids in different environmental and operational conditions will be performed.
Update:
- Fluids to test have been selected and experimental program design set.
- On-line DGA monitors continue to be evaluated.
Task: Membrane technologies for online, low-maintenance dry-out of transformers.
Task Description: EPRI research has developed novel concepts for continuous on-line dry-out of transformers without the need for cartridge replacement. In 2025, research will enhance the on-line dehydration technology using Peltier cooling. The results will be a smaller and more efficient technology. Field pilots in utility substations will continue to validate the technology and refine the concepts.
Update:
- Two new pilot units are being assembled for field deployment.
- The field deployments will allow for even greater learning beyond the laboratory.
Engagement Opportunities
| Meeting | Date | Location | Information |
|---|---|---|---|
| EPRI Kick Off Webcast: Transformer Life Management & Polymer Bushing Life Management | February 7 11:00am - 12:00pm ET | Webcast | Meeting Material |
| Transformer Life Management & Bushings Task Force - March 2025 | March 10-13 (In-person)/ March 17-20 (Virtual) | Charlotte, NC | Register Here |
| EPRI Substations (Program 37) New Supplemental Launch Webcast | April 8, 2:00-3:00 pm ET | Webcast | Meeting Materials |
| Copper Book Technical Webinar 1: Power Transformers 101 | April 29, 11:00 am - 12:00 pm ET | Webcast | |
| Copper Book Technical Webinar 2: On-line monitoring technologies for Power Transformers | June 19, 11:00 am - 12:00 pm ET | Webcast | |
| EPRI R&D Project Update Webcast: Transformer Life Management & Polymer Bushing Life Management (P37.101 & P37.113) | June 25, 11:00 am - 12:00 pm ET | Webcast | Meeting Materials |
| EPRI Substations (Program 37) 2026 Membership Rollout 1 | June 26, 11:00 am - 12:00 pm ET | Webcast | Meeting Materials |
| EPRI Substations (Program 37) 2026 Membership Rollout 2 | July 31, 1:00 pm - 2:00 pm ET | Webcast | Meeting Materials |
| Copper Book Technical Webinar 3: Beyond Dissolved Gas Analysis: Assessing remaining life of Power Transformers | August 6, 11:00 am - 12:00 pm ET | Webcast | |
| Transformer Life Management & Bushings Task Force | August 18-22, 11:00 am - 12:00 pm ET | Task Force | Meeting Materials |
| Copper Book Technical Webinar 4: Oil Quality: How to effectively interpret results and make decisions | October 15, 11:00 am - 12:00 pm ET | Webcast | |
| Copper Book Technical Webinar 5: Bushings 101 | December 3, 11:00 am - 12:00 pm ET | Webcast |
Anticipated 2025 Deliverables
| Deliverable | Description | Date |
|---|---|---|
| EPRI Power Transformer Guidebook (The Copper Book) 2025 update | The 2025 EPRI Power Transformer Guidebook will include the latest updates based on ongoing research and industry advances and continue adding valuable single-page quick reference guides for key topics. | December 2025 |
| Technical webinars on the Transformer Guidebook | Regular webinars are developed for project funders on key topics in the EPRI Power Transformer Guidebook. | December 2025 |
| Assessment of transformer online monitoring technologies to help members in specification development | New self-calibrating online DGA technology and new bushing monitoring technologies will be added to the wide array of monitors under assessment. | December 2025 |
| Novel fluids for transformers | Through well-defined test protocols, input from users, and emerging literature, the research looks to provide valuable guidance on the opportunities, uses, and challenges associated with alternative fluids. | December 2025 |
| Membrane technologies for online, low-maintenance dryout of transformers | The 2025 research aims to explore enhancing unit water extraction efficiency. In addition, piloting of smaller and longer lasting units using solid-state Peltier technology plan to be performed. | December 2025 |
| New oil markers to aid power transformer diagnostics | The 2025 results strive to enhance the value gained from oil samples through exploring the dynamics of newly identified health markers—allowing for greater insights into the transformer health condition. | December 2025 |
2024 Deliverables
| Product ID | Name |
Type |
|---|---|---|
| TBD | EPRI Power Transformer Guidebook (Copper Book) 2024 update |
Technical Update |
| TBD | Technical webinars on the Transformer Guidebook |
Technical Update |
| TBD | Transformer online monitoring technologies: Laboratory testing to help members in specification development |
Technical Update |
| TBD | Alternative fluids for transformers for increased ratings, extended service life, and reduced environmental impact |
Technical Update |
| TBD | Membrane technologies for online, low-maintenance dry-out of transformers |
Technical Update |