Objective
The project objective is to effectively use existing data streams of voltage and current to evaluate substation equipment health. The focus of this project is on voltage and current signals that are already being measured for other functions (i.e. protection, control, metering) and readily available in many substations, without the need for additional sensors specific to asset health monitoring. Research interests include improved understanding of online voltage and current waveforms as indicators of asset health, evaluation of the effectiveness of commercial solutions, and development of novel techniques.
Research Value
The project can provide the following benefits:
- Improved risk assessment of substation assets using minimal quantities and types of data
- Reduced operation and maintenance (O&M) cost for monitoring major substation equipment health
- Increased reliability of power supply through early warning of asset failures
- Enhanced safety by reducing unexpected catastrophic equipment failure
Planned 2025 Research
This project seeks to enhance knowledge of incipient failure in the following ways:
 
  Evaluate capacitively coupled voltage transformer (CCVT) or voltage transformer (VT) signals across CCVT/VT degradation: This project intends to catalog Instrument transformer failure signatures to link incipient failure to various voltage waveforms. Research may be performed on a combination of computer models and some quantity of physical assets, depending on the level of member engagement. The project intends to stress CCVTs or VTs to push them toward failure through thermal cycling and overvoltage tress, with additional waveform data collected and compared to baseline. The forensic examination of failed devices may identify which CCVT component failure was the primary cause of degradation, possibly offering a link between waveforms and specific component degradation. The intention of this task is to improve our understanding of the complexities of instrument transformer failure, gather data for future development of failure detection algorithms, and enhance EPRI’s skill set of CCVT or VT forensic analyses for member applications.
Evaluate link between voltage/current data and state-of-the-art transformer failure indication techniques: This research constitutes a review of literature to examine what transformer failure detection techniques or algorithms have been proposed but not yet developed into commercial technologies. The intent of this task is to identify which methods may be most promising to transition from a theoretical space to more applied evaluation in a substation test bench or controlled high-voltage field deployment by EPRI and its members near term.
Anticipated 2025 Deliverables
| Deliverable | Date | 
|---|---|
| Evaluation of Voltage Recordings During VT Failure (Technical Report) | December 31, 2025 | 
| Methods to Evaluate Large Power Transformer Health Using Online Voltage and Current Measurements (Technical Report) | December 31, 2025 |