In 2026 we are planning to undertake several tasks in P35.019, HVDC Lines, including those listed below:

  • Update HVDC Electrical Effects Module in TLWorkstation: Based on the results and data obtained from the reduced-scale, full-scale, and operational line measurements, the existing algorithms used in the EPRI TLWorkstation software tool intend to be updated and the user interface improved.
  • Update HVDC Transmission Line Reference Information: This task intends to update the Overhead Line specific HVDC reference documents which was previously published by EPRI in the early 1990’s. This document details the design characteristics of existing lines, and describes the testing conducted and results obtained in determining the corona and electric field characteristics of HVDC transmission lines.
  • Update HVDC Line Design Guide: This task, updated each year collects relevant information on HVDC line designs from various completed HVDC research tasks. Topics will include design aspects pertinent to HVDC and will identify areas of design that are similar between dc and ac. The guide is updated each year with new information.
  • Perform Live-Line Tool Testing: This task intends to test live-line tools under HVDC conditions. The plan is to investigate the effects of space charge and corona to determine their impact on the flashover performance and voltage distribution along the length of the tool. Work might also be done to determine the accuracy of voltage detection devices under HVDC conditions.
  • Evaluate Insulator Dimensioning for Contaminated Environments: Contamination is the main driver for insulation coordination of HVDC lines. Contamination performance of DC is vastly different from AC. This task intends to determine the latest state of the science in HVDC insulator dimensioning for contaminated environments. Testing and long-term aging of insulator materials may also be carried out.
  • Update HVDC Reference Book (The Olive Book): An electronic version of the updated HVDC reference book will be made available to project funders. This reference book, updated each year, contains information on overhead lines and converter stations.
  • Perform Hardware and Insulator Corona Tests: When specifying corona requirements for HVDC insulator hardware assemblies, many utilities use the equivalent peak ac voltage for testing. Currently, no HVDC hardware corona test specifications exist. This task intends to develop test specifications based on laboratory testing and develop guidelines to assist in specifying corona tests for HVDC hardware. In 2026 the intent is to review numerical simulations and to update the testing protocols.

2026 Engagement Opportunities

Event Name Date Location Contact Information
Transmission and Substations Task Force Meeting February 9 - 12 Charlotte, NC EPRI Offices Rachel Moore Meeting Information
EPRI Project Update Webcast: High Voltage Direct Current Converter Stations and FACTS (P35.019, P36.008, P37.116) EPRI March 6 11:00 am - 12:00 pm ET Webcast Gary Sibilant Meeting Information
Transmission & Substations Advisory Meeting March 30 - April 1 Charlotte, NC EPRI Offices Rachel Moore Meeting Information
EPRI R&D Information Exchange Webcast: High Voltage Direct Current Converter Stations and FACTS (P35.019, P36.008, P37.116) June 5 11:00 am - 12:00 pm ET Webcast Gary Sibilant Meeting Information
Overhead Transmission 2025 ARP Rollout #1 June 18 10:00 - 11:30 am ET Webcast Rachel Moore Meeting Information
Overhead Transmission 2025 ARP Rollout #2 July 30 10:00 - 11:30 am ET Webcast Rachel Moore Meeting Information
Transmission and Substations Task Force Meeting August 10-14 Charlotte, NC EPRI Offices Rachel Moore Meeting Information
Transmission & Substations Advisory Meeting August 31- September 2 Gaylord National Resort & Convention Center, National Harbor, Maryland Rachel Moore Meeting Information
EPRI GET SET Webcast September 2026 September 10 Webcast Victor Diez Meeting Information
EPRI 765 kV Workshop Lenox - Sept 2026 September 14 - 18 Lenox MA Rachel Moore Meeting Information
EPRI's PTX-AI Accelerator Initiative - September 2026 September 23, 11:00am - 12:00pm, ET Webcast Bhavin Desai Meeting Information
EPRI BVLOS Technical Deep-Dive: Voltair Labs (October 2026) October 8, 2:00 pm - 3:00 pm ET Webcast Drew McGuire Meeting Information
EPRI End of Year Webcast: High Voltage Direct Current Converter Stations and FACTS (P35.019, P36.008, P37.116) November 20 11:00 am - 12:00 pm ET Webcast Gary Sibilant More information coming soon

2026 Anticipated Deliverables

Deliverable Type
HVDC Reference Book (The Olive Book) Reference Book
TLW Gen 2 – HVDC Electrical Effects Module Software
HVDC Corona Testing Evaluation Technical Update
HVDC Transmission Line Design Guide Technical Update

2025 Engagement Opportunities

Meeting Date Location Information
EPRI Kick Off Webcast: High Voltage Direct Current Converter
Stations and FACTS (P35.019, P36.008, P37.116)
January 31
8:00-9:00 am PT
Webcast Meeting Materials
High Voltage Direct Current
Task Force
March 10-13 (In-person)
March 17-20 (Virtual)
Charlotte, NC Meeting Materials
EPRI Overhead Transmission Program (P35) New Supplemental Launch Webcast April 3, 2:00pm - 3:00pm ET Webcast Meeting Materials
EPRI R&D Information Exchange Webcast: High Voltage Direct Current Converter
Stations and FACTS (P35.019, P36.008, P37.116)
June 27
8:00-9:00 am PT
Webcast Meeting Materials
Overhead Transmission 2026 ARP Rollout #1 July 17
10:00 am - 11:00 pm ET
Webcast Meeting Material
Overhead Transmission 2026 ARP Rollout #2 July 24
2:00 pm - 3:30 pm ET
Webcast Meeting Materials
High Voltage Direct Current
Task Force
August 18-22 (In-person) Charlotte, NC Meeting Materials
EPRI End of Year Webcast: High Voltage Direct Current Converter
Stations and FACTS (P35.019, P36.008, P37.116)
November 21
8:00-9:00 am PT
Webcast Meeting Materials

2025 Deliverables

PID Deliverable Title
3002032808 HVDC Reference Book (Olive Book)
3002032810 TLW Gen 2 - HVDC Electrical Effects Module
3002032811 HVDC Overhead Transmission Line Design Guide
3002032812 HVDC Line Parameters and Testing Guide